Hybrid System Maintenance
Comprehensive maintenance services for hybrid solar systems with battery backup
Battery Maintenance
Essential maintenance for different types of batteries
Lead Acid Batteries
Maintenance Schedule:
Lithium Ion Batteries
Maintenance Schedule:
Battery Maintenance Tips
Temperature Control
Maintain battery room temperature between 20-25°C for optimal performance
Water Level (Lead Acid)
Maintain distilled water level between min-max marks. Never use tap water
Charge Levels
Avoid complete discharge. Keep batteries between 20-80% charge for longer life
Ventilation
Ensure proper ventilation in battery room to prevent gas accumulation
Hybrid AMC Plans
Annual Maintenance Contract plans for worry-free operation
Basic AMC
Exclusions:
- Replacement Parts
- Emergency Visits
- Major Repairs
Standard AMC
Exclusions:
- Battery Replacement
- Major Component Replacement
Premium AMC
Exclusions:
- Only covers labor for major replacements
Troubleshooting Guide
Common issues and solutions for hybrid solar systems
No Backup During Power Cut
Symptoms:
- Inverter beeping continuously
- Battery indicator not showing charge
- No output from inverter during grid failure
Possible Solutions:
- Check battery connections
- Verify battery voltage (should be >48V for 5kW system)
- Check inverter error code
- Reset inverter by switching off and on
Low Solar Generation
Symptoms:
- Solar generation lower than expected
- Batteries not charging fully
- More grid consumption than solar
Possible Solutions:
- Clean solar panels
- Check for shading on panels
- Verify inverter MPPT operation
- Check weather conditions
Battery Not Holding Charge
Symptoms:
- Backup time reduced significantly
- Battery discharges quickly
- Battery voltage drops rapidly under load
Possible Solutions:
- Check battery water level (for lead acid)
- Perform equalization charge
- Check battery age (replace if >3-5 years)
- Verify charging voltage
Inverter Not Switching to Grid
Symptoms:
- System runs on battery even when grid is available
- Grid indicator not showing on inverter
- No net metering/export happening
Possible Solutions:
- Check grid voltage at inverter input
- Verify grid connection settings
- Check grid frequency (should be 50Hz)
- Reset inverter settings
Remote Monitoring
Monitor your hybrid system performance from anywhere
Monitoring Features
Real-time Monitoring
Monitor solar generation, battery status, and consumption in real-time
Mobile App Access
Access system data through mobile app on Android and iOS
Alerts & Notifications
Get instant alerts for system faults, low battery, or low generation
Performance Reports
Monthly and annual performance reports with savings analysis
Setup Requirements
Setup Cost: ₹5,000 - ₹10,000
One-time cost including device and installation